Delay time, Auto ingredient / manual pen advance, Mix timer – Digi-Star EZ4300 User Manual
Page 19: Operators manual

Operators Manual
D3655
15
Delay Time
The delay time feature allows an operator to select the amount of time the scale
should wait before automatically advancing to the next ingredient or pen. This
helps insure accuracy for the ingredient or pen amount. For example, if the delay
time is set to 10 seconds and the preset alarms are activated continuously, the
auto-advance starts the Delay timer. If the preset de-activates, the delay timer is
reset, therefore assuring that the preset weight amount has to be met for the total
delay time amount.
Setting the Delay Time to manual prevents the scale from ever auto-advancing,
regardless of the weight.
To Change the Delay Time
Enter short cut number: 443 and press [Select].
Press [Select] to select the delay time (In seconds).
Press [On] to store the setting.
Delay Time Selections in Seconds: Manual, 1, 2, 3, 5, 7, 10, 20, 30, or 60.
Note: Set to Manual to prevent automatic advance after the ingredient or pen amount
has been reached.
Auto Ingredient / Manual Pen Advance
Use this option when you require that the ingredients automatically advance and
manually advance between pens.
To change this option, enter short cut number “461” and then press [Select].
Press [Select] to toggle between on/off.
Press [On] to store the setting.
Mix Timer
Press [Timer/Counter].
Use the numeric keypad to enter the amount of time.
Press [Timer/Counter].
The timer will begin to count down, when the timer has reached zero, the alarm
light and buzzer will turn on
Press [Clear] to enter the weighing mode.
Press the [Recipe] or [Pens] key to re-enter the batching mode.