Menu 2 – Delta Dore 217 TYBOX Installation User Manual
Page 3
MENU 2
>5s
1
0
1
2
3
4
5
EXIT
1
0
Press button 2.
To change the different settings, press
the + or - buttons, then press the OK button
to confirm and move on to the next setting.
Turn the selector dial to
,
then press the
i button for 5
seconds.
To exit the mode,
turn the selector dial
to another mode.
Permission to change
Programme and settings
0 : Modifications permitted to
programme and settings
1 : Modifications to programme
not permitted and adjustment of
settings limited.
Tybox 1x7 : Comfort setting
limited between 16 and 22°C.
Tybox 2x7 : +/- 3°C +/- 3°C either
side of the last setting.
Tybox 1x7
Tybox 2x7
X
X
: 5°C <
< 30°C
: 5°C <
< 16°C
16°C <
< 22°C
13°C <
< 19°C
5°C <
< 11°C
+/- 3°C
PROG
Temperature displayed in AUTO mode
0 : Continuous display of the
temperature setting.
In this case, press the i
button to display the room temperature
1 : Continuous display of the room
temperature.
In this case, press the
i button
to display the temperature setting
Tybox
1x7
Tybox
2x7
X
Automatic time change
(summer/winter time)
Tybox
1x7
Tybox
2x7
X
X
Non
Oui
Time display mode
12h-24h
Tybox
1x7
Tybox
2x7
X
X
24h
12h
Measured temperature correction
(-5°C à +5°C par pas de 0,1°C).
Example: If the temperature dis-
played
on the device is 19°C and the
observed temperature is 20°C,
adjust the temperature by +1°C,
then confirm by pressing OK.
Tybox
1x7
Tybox
2x7
X
X
- 5°C <
< +5°C
Before changing this setting,
the device must have been in
operation for at least 2 hours.
Time before boiler maintenance
(0 to 365 days)
Reprogramme after
each maintenance operation
Tybox
1x7
Tybox
2x7
X
X
--- (0) to 365 days