Fuse replacement, General specifications – Dataprobe PowerPal Single User Manual
Page 8

POWER PAL
Page 8
Extension Device
Connect any device that would normally be used on the telephone line to PowerPal’s modular jack marked EXT.
(Pulse phones will not work)
Phone Line
Connect the RJ11 Jack marked LINE to the telephone line.
FUSE REPLACEMENT
In the event that the device connected to Pal fails to power up when commanded to, inspect the fuse located at the
rear of PowerPal. Before removing the fuse, disconnect Pal from its A/C source. Then remove the fuse by
rotating the top of the fuse holder with a screwdriver.
If the fuse is visibly damaged, replace it with the same type and rating 250V 10 Amp fuse (5 X 20 mm).
GENERAL SPECIFICATIONS
Electrical
120 VAC 60 Hz. , 10 Amps maximum switching capacity
Total power = Connected load + 60 Watts
Physical
Table top unit - UL 94V-0 rated plastic
Dimensions - 9.00 D x 4.50 W x 3.25 H
Weight - 2.0 lbs.
UL & cUL Listed Telephone Equipment. File No. E174117