beautypg.com

Dataprobe PowerPal Single User Manual

Page 6

background image

POWER PAL

Page 6

Answer Mode

6 1

Normal Answer Mode

ß Factory Setting

6 2

Answer and Prompt

6 3

Answer and Quiet

6 4

Answer and Dial Tone

No. of Rings before Pal Answers the Call

2 n

n = Number of rings (1-6)

Factory Setting = 1

No. of Rings to the Extension before Pal Terminates the Call

7 n

n = Number of rings (1-6)

Factory Setting = 6

Power Reset Time

9 n

Set in 5 second increments

Factory Setting =10 sec.

(n = 1-9 for 5 to 45 seconds)

Call Completion

4 0

Power is turned off after call completion (See 8 n

)

4 1

Power remains in current state

ß Factory Setting

on call completion

8 n

Delay time for off after call completion (40

)

Delay is set in 10 second increments
(n = 1-9 for 10 to 90 seconds)

Security

# c

Security set to code ‘c’ (1 to 6 digits)

5 0

Security Off

ß Factory Setting

5 1

Power Only Secure

5 2

Power and Extension Secure