beautypg.com

Dataprobe T-APS Standalone User Manual

Page 9

background image

V130201E

T-APS Users Manual

Page 9

1E-3 = 1 x 10

-3

Once the Line Code Violation Error Ratio exceeds the preset threshold value, it will then switch the ACTIVE
PATH to the PROTECTION PATH.

D: SET LCV CLEAR RATIO

Set Line Code Violation Error Ratio

Selections:
1E-9 = 1 x 10

-9

1E-8 = 1 x 10

-8

1E-7 = 1 x 10

-7

1E-6 = 1 x 10

-6

1E-5 = 1 x 10

-5

Once the Line Code Violation Clear Ratio achieves the preset threshold value, it will then switch back from
PROTECTION PATH to the ACTIVE PATH.

E: SET FRAME ALARM RATIO

Selections:
1E-5 = 1 x 10

-5

1E-4 = 1 x 10

-4

1E-3 = 1 x 10

-3

1E-2 = 1 x 10

-2

1E-1 = 1 x 10

-1

Once the Line Code Violation Error Ratio exceeds the preset threshold value, it will then switch the ACTIVE
PATH to the PROTECTION PATH.

F: SET FRAME CLEAR RATIO

Selections:
1E-7 = 1 x 10

-7

5E-6 = 5 x 10

-6

1E-5 = 1 x 10

-5

1E-4 = 1 x 10

-4

1E-3 = 1 x 10

-3

Once the Line Code Violation Clear Ratio achieves the preset threshold value, it will then switch back from
PROTECTION PATH to the ACTIVE PATH.