Alarm contacts – Dataprobe T-APS Standalone User Manual

Page 12

background image

V130201E

T-APS Users Manual

Page 12

NC

NO

COM

8. Alarm Contacts

Alarm

The Alarm relay Contact definition:

NC Contact - Closed conditions:

1. Power supply OFF.

2. Circuited error detected, and T-APS switches from working path to protection path. Failure LED

will be also ON. Once all errors have been cleared, T-APS will switch back to working path, and
the NC contacts will return to an open state and the Failure LED will then be OFF.

NC Contact - Open conditions:

1. Power supply ON.

2. T-APS operating normally in working path.

There is a self-diagnostic test feature built into the T-APS which will change the contacts in the event of T-APS
unit failure.

Contacts shown in de-energized state,
T-APS is powered Off. COM is connected to
NC