Maintenance and Troubleshooting

4-10

Entire display fails to work.

Check for proper line voltage into the power

termination panel.

Check for correct power to controller and

modules.

Check/replace the ribbon cable from the

controller to the modules.

Check the voltage settings on the power

supplies.

Check/replace the signal cable to the

controller.

Replace the controller.

Verify proper use of the software in the V1500

Controller manual (ED13530).

Temperature always reads –196F/-127C
degrees F/0 degrees C

Check temperature sensor connections.

Replace the temperature sensor.

Replace the controller.

Display is stuck on bright or dim.

Check Manual/Auto dimming in Venus 1500

software.

Check light detector cable.

Check the address on the Light Sensor.

Check light detector for obstructions.

Replace the light detector.

Replace the controller.

4.10 Initialization Operation Information

Every time the display is operated, the display will run through an initialization in
which it will display the following:


1. Product Name (Galaxy®)
2.
Display Size (Row x Column)
3.
Shading (64 Mono)
4.
Bootloader Version (OS X.XX)
5.
Firmware Number (ED-13305)
6.
Firmware Revision (Rev X.XX)
7.
Hardware Address (HW:XX)
8.
Software Address (SW:XX)
9.
IP Address: ((default) IP: 172.16.192.25)
10.
Subnet Msk: ((default) Msk: 255.255.0.0)
11.
COM1 Configuration (C1:V15) ((Modem C1:V15) If a Modem is present)
12.
COM 2 Configuration (C2: RTD)
13.
Socket 3001: (IP 3001: V15)
14.
Socket 3002: (IP 3002: RTD)
15.
Line Frequency (CLK: AUTO (60))
16.
Display Name Description (Galaxy Row x Column)