3.9 Signal Termination Between Two (or More) Signs

Reference Drawings:

System Riser Diagram, Modem ..................................... Drawing A-88426

System Riser Diagram, RS422 ...................................... Drawing A-92681

System Riser Diagram, RS232 ...................................... Drawing A-96058

System Riser Diagram, Fiber....................................... Drawing A-110559

Schem; Fiber, Modem, RS422 Surge Protector Input . Drawing A-125900

Signal Input, Outdoor Venus 1500............................... Drawing A-129110

System Riser Diagram, Radio ..................................... Drawing A-185325

RS422 Interconnection

This is the most common method of terminating signal between two or more signs. A
6-conductor cable is used. One end terminates to the “RS422 OUT” 6-position
terminal block (A31-TB3) on the controller in the first display. The other end of the
cable will terminate on the “RS422 IN” 6-position terminal block (A31-TB2) on the
controller of the second display.

Figure 32: Signal Termination Panels


Face A – RS422

OUT

(A31-TB3)

Field

Cabling

Face B – RS422

IN

(A31-TB2)

Pin 1 (GND)

Green

Pin 6 (NC)

Pin 2 (O-)

Blue

Pin 5 (I-)

Pin 3 (O+)

White

Pin 4 (I+)

Pin 4 (I-)

Brown

Pin 3 (O-)

Pin 5 (I+)

Black

Pin 2 (O+)

Pin 6 (GND)

Red

Pin 1 (NC)










Electrical Installation