Service and diagnostics, Service and diagnostics -3, Figure 34: general display component layout – Daktronics AF-3112-34-R,A User Manual

Page 39: 4 service and diagnostics

background image

4.4 Service and Diagnostics

Reference Drawings:

F. Assy, AF-3112-2480-34........................................... Drawing B-200259
Schem, AF-3112-8-32X***-34mm-Mono-PM............... Drawing C-200002

Remember: Disconnect power before servicing any internal components.

The following sub-sections address servicing of the following display components:

transformer, RFI filter

controller

modules, drivers and power supplies

The sub-sections also address any diagnostic LEDs, fuses, and signal/power
connectors found on the unit. A general display component layout is shown in
Figure 34. See the schematic, Drawing C-2000002, for exact number of fans and
power supplies used for your display size and see Drawing B-200259 for component
locations. Note: The controller, light sensor, and quick connect output board are
only loaded in the primary display.

Figure 34: General Display Component Layout

The table below give the part number for some of the various components used in
your display. In addition, the label on the part can also be used for further
identification.

Component

Denoted As

Location

Filter and Transformer

0A-1301-0501(Primary)

0A-1301-0502 (Mirror)

Inside the power termination box

Controller

0A-1229-0005

Inside the controller/power panel

(behind the bottom left module)

Modules 0P-1301-1000

Over entire face of the display

(includes driver)

Power Supplies

A-1591 (red)

A-1633 (amber)

Behind modules (refer to the

display’s Schematic)

Light Detector

0A-1301-0500

In top left corner of door

Maintenance and Troubleshooting

4-3