Loop-Back test with Fiber

Fiber Optic Communication Manual

9

1. Locate the fiber optic board in the signal termination

enclosure.

2. Label the fiber ends connected to the board and carefully

remove them as shown in

Figure 11

.

3. Connect the ends into the fiber splice (Daktronics part# P-

1197), as shown in

Figure 12

.

4. When the fibers are connected, perform the loop-back test

using the Venus 1500 software as described in
Conducting the Venus 1500 Software Test

Figure 11: Fiber Optic Board

Figure 12: Connecting TX and RX Fibers with Fiber Splice


Conducting the Venus 1500 Software Test

1. Open Venus 1500 Administrator.











2. Click on Network Configuration and open the direct network by clicking on the

[

+]

in front of Direct Network.