beautypg.com

Installation, Continued, For built-in installation – Desa FDCFRN User Manual

Page 15

background image

www.desatech.com

111244-01C

15

For Built-In Installation

WARNING: A licensed elec-

trician must connect the wiring
harness to electrical supply fol-
lowing all local codes. Electri-
cian must provide a clamp on
the box cover to secure the wir-
ing. Wiring should be routed
through the bushing in the hole
on the outer casing of fireplace.

1.

Install snap bushing from blower kit into one
hole on rear of remote/blower bracket (see
Figure 17). The other hole is for a strain relief
clamp (not supplied) to secure incoming elec-
trical supply.

2.

Follow steps 2 through 6 in Installing Blower
Accessory
, page 14.

3.

A licensed electrician must follow the wiring
diagram to connect incoming electrical sup-
ply to fan kit wiring harness (see Figure 18).

4.

Plug power cord to outlet receptacle (not pro-
vided) as shown in Figure 17. Wind extra cable
of power cord and tie up with plastic wire strap
(see Figure 17). Set cable bundle between the
remote/blower bracket and outer casing, away
from the burner.

INSTALLATION

Continued

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Figure 18 - Wiring Diagram For Blower

Accessory Built-In Installation

3
2
1

O

F
F

P

IL

OT

O

N

H

I

L

O

Blower Bracket
Assembly

Screw

Wire Harness

Switch
Plate

Switch

Power Cord

Outlet Receptacle
(not included)

Remote/ Blower
Bracket

Clamp Connector
(not included)

5.

Test to make sure blower is working properly.

6.

Reinstall upper louver beginning with bottom
screws (see Figure 11, page 12) and close
lower louver.

Extension Cord

Use extension cord if needed. The cord must have a
three-prong, grounding plug and a three-hole recep-
tacle. Make sure cord is in good shape. It must be
heavy enough to carry the current needed. An under-
sized cord will cause a drop in line voltage. This
will result in loss of power and overheating. Use a
No. 16 AWG cord for lengths less than 50 feet.

Figure 17 - Installing Blower Bracket Assembly

Plastic Wire Strap Wire Harness

Lower Louver Door

This manual is related to the following products: