CREATOR SPRO-CON9000 User Manual
Page 30

CREATOR Corporation China 2010-05 WWW.CREATOR1997.COM
38
User’s Manual for SPRO Network Control Host Series
● Monitor Manager software in the host cannot find a
certain network device. Possibly the communication port
of the network device is damaged. Please ask
professional staff for maintenance.
Serial communication device is out of control
● See whether the communicating connection pins in the
serial communication device to be control are correctly
connected (In RS-232 protocol, RX end should be
connected to TX transmitting end; In RS-485 protocol, “+”
end should be connected to “-”end)
● See whether the configurations of baud rate, stop bit,
parity of the device to be controlled are the same as those
of Control system program.
● See whether the control code in the device to be
controlled is the same as those in Control System
program.
● Checking by computer, to find there is no control code
output from the serial port of the system host. Please
change the communication port or ask professional staff
for maintenance.
CREATOR CORPORATION(CHINA)
Copyright by CREATOR
Last Revision:08/2010