SPEED CALIBRATION
The speed calibration is not required unless you have changed out the stock transmission, pulley, or tires.
ADJvST
ADJvST
ADJvST
ADJvST
Adjust
•
Press and release the switch until “
AdJvSt
” is displayed, then press and hold the switch until “
-
” is displayed.
•
Release the switch. The display will show “
fast
“ or “
sLOWX
”. Fast will allow you to increase the speedometer reading, slow will
allow you to decrease the speedometer reading.
•
Press and release the switch to change, press and hold the switch to continue. The display will change to “
CL
” and a number from
0.75 to 1.25. This is the calibration ratio that is applied to the reading that the ECM is providing. 1.10 will be 10% faster, 0.90 will
be 10% slower.
Actual speed
----------------------------- x current cal ratio (1.00 by default) = new cal ratio speedometer reading
•
Press and release the switch to change the cal ratio. When the desired cal ratio is shown, press and hold the switch to save it.
vNIT
vNIT
vNIT
vNIT
Speed unit
•
Press and release the switch until “
vnit
” is displayed, then press and hold the switch until “
-
” is displayed.
•
Release the switch. The display will light up the current speed unit (MPH or km/h).
•
Press and hold the switch to keep the current unit or press and release the switch to change the unit.
•
Press and hold the switch until “
-
” is displayed to save the setting.
S SET
S SET
S SET
S SET
Miles to Next Service setup
The service mileage is a countdown mile meter. The service mile display can be disabled or can be set to count down from
500 – 7500 miles. If the service mileage is enabled and it gets to 0 miles it will display “
S -DvE
” each time the key is turned on. If the
push button switch is pressed and held while “
S -dve
“ or “
S
” and a mileage is displayed, the service miles will be reset to your preset
value.
•
Press and release the switch until “
S set
” is displayed, then press and hold the switch until “ – ” is displayed.
•
Release the switch. The current setting will be displayed, “
OFF
” or a mileage from
500
-
7500
.
•
Press and release the switch until the desired setting is displayed.
•
Press and hold the switch until “
-
” is displayed to save the setting.
PERF
PERF
PERF
PERF
Performance menu setup
The performance readings can be turned on or off. When they are turned off the odometer display will only toggle through the
mileage readings.
•
Press and release the switch until “
PErF
” is displayed, then press and hold the switch until “
-
” is displayed.
•
Release the switch. The current setting will be displayed (
on
or
oFF
).
•
Press and release the switch until the desired setting is displayed.
•
Press and hold the switch until “
-
” is displayed to save the setting.
nIgHt
nIgHt
nIgHt
nIgHt
Night Dimming
Your display system has a dimming feature that dims the display intensity automatically at night. Normally the system is at full
brightness for daytime viewing. To have the system at full brightness all of the time, go into the setup menu as described above and
select “
ngt
” (night). Press and release the function switch to select “
OFF
” instead of “
on
”. Press and hold the function switch to save
the new setting.
•
Press and release the switch until “
nIgHt
” is displayed, then press and hold the switch until “ – ” is displayed.
•
Release the switch. The current setting will be displayed. (
ON
,
OFF
).
•
Press and release the switch until the desired setting is displayed.
•
Press and hold the switch until “
-
” is displayed to save the setting.
W
WW
WX
XX
XArn
Arn
Arn
Arn
RPM
Rpm warning setup
The rpm warning/shift point can be adjusted from 2000 – 7500.
•
Press and release the switch until “
WXArn
RPM
” is displayed, then press and hold the switch until “
-
” is displayed.
•
Release the switch. The current warning point will be displayed on the bar graph.
•
Press and release the switch until the desired setting is displayed.
•
Press and hold the switch until “
-
” is displayed to save the setting.
W
WW
WX
XX
XArn
Arn
Arn
Arn
V
Voltage warning setup
•
Press and release the switch until “
WXArn
V
” is displayed, then press and hold the switch until “
-
” is displayed.
•
Release the switch. The current warning point will be displayed (
9
.
0
–
12
.
1
).
•
Press and release the switch until the desired setting is displayed.
•
Press and hold the switch until “
-