2 functions and features, 3 technical parameters, 3 cr-ir2001-12 infrared radiation panel – CREATOR Digital Conference System User Manual
Page 48: 1 panel functions instruction
CREATOR CHINA 2010-09 WWW.CREATOR1997.COM
39
User
’s Manual of Intelligent Digital Conference System
③ SINGAL OUTPUTS
——connect to infrared
radiation panel
④ TEST
——test key
⑤ POWER INPUT
——power input, support
AC100V~240V
5.2.2 Functions and Features
◆ Infrared transmission frequency(2M-8MHz);
◆ General audio testing signals with 12 different
frequencies for the convenience of system
testing;
◆Undertaken high pressure resistant test
(3500V), ensure in accordance with safety
regulation;
◆ Adopt metal material shell in the controller, with
8000V anti-static power.
5.2.3 Technical Parameters
Model
CR-IR2000-12
Power
Switch power 100-240V
power
Consumption
15W/25W(optional)
Crystal oscillator
Crystal control
Modulation
(PPL)freq modulation,narrow
band
Carrier
wave
frequency
2M
—20MHz (BAND4)
Pre-emphasis
100μs
Deviation
±6kHz(peak value ±7kHz)
Total
harmonic
distortion
<1%
SNR
>80dB
Frequency
response
20~10KHz
Input sensitivity
50mV-1.5V(lineLEV)
RF output
2 ways of BNC short-circuit
resistant jack,100mV RMS
RF
output
Impedance
75Ω
Dimension
483L x 344W x 88H (mm)
Weight
About 6KG
Color
Grey
5.3 CR-IR2001-12 Infrared
Radiation Panel
5.3.1 Panel Functions Instruction
Rear panel:
Front panel:
① LOW/HIGH
——Low and high radiation
power switch
② IN
——Connect to the SIGNAL OUTPUTS
port in infrared transmission controller, or OUT
port in front infrared radiation panel.
③ OUT
——Connect to the IN port in next
infrared panel.