Digicast Media Router S2 Receiver CMR-5975 (MR-S2)

Revision 3

Device Management via User Interfaces

MN-CMR5975-IOM

4-56

To modify code via Telnet:

Step

Procedure

1

Start up Solarwinds TFTP server – Ensure configuration as described
previously.

2

Ensure that the code provided by CEFD is located in the TFTP Root
directory.

3

Start up Telnet client and initiate a session with the MR-S2 as described
in the Telnet Interface section

4 Select

A’ for Administration

5 Select

D’ for Download

6 Enter

1’ for Application code or ‘2’ for FPGA code (the user will be

directed to select Application or FPGA code in the download
instructions provided by CEFD when new code is provided)

7

Enter the IP address of the TFTP server and wait for the message
Upgrade complete. Press any key to continue

This code modification process can also be conducted via the Web Interface, under the
Administration page, or the Terminal Interface under the Main Menu.





IMPORTANT

Under heavy traffic conditions, the TFTP transfer may take several
minutes. The transfer process reported by Solarwinds may show greater
than 100% transferred, but this is a normal condition. Be patient and
allow the transfer to take place.