beautypg.com

Comtech EF Data CMR-5975 Manual User Manual

Page 46

background image

Digicast Media Router S2 Receiver CMR-5975 (MR-S2)

Revision 3

Device Management via User Interfaces

MN-CMR5975-IOM

4-18

Select the “Service List” button at the bottom of the page to see all services on the particular
input. This is achieved by looking at the Program Stream Information (PSI) that is contained in
the Program Association Table (PAT) and Program Mapping Table (PMT) – all detected
programs will be displayed for either input port selected.


Enable

Enables or disables the route.

Name

The name of the incoming program that is extracted from the Program Service Information.


Program Number

The program number, as defined in the service list, to be routed to the Ethernet as Transport
Stream over IP.


PMT PID Number

The PMT PID to be routed to the Ethernet as Transport Stream over IP.

Destination IP

The IP address to be used when routing the Transport Stream over Ethernet IP.

Port Number

The Port Number to be used when routing the Transport Stream over Ethernet IP.