Customer Commands

MN/XPA200OD.IOM

17

Command

(Instruction

Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(note that all arguments are ASCII numeric

codes, that is, ASCII codes between 48 and 57)

Response to

Command

(target to controller)

Query

(Instruction

Code and

qualifier)

Response to

query

(target to

controller)

Force Back-Up

State

FBU= 1

byte,

value of 0, 1, 2

Command or Query
Force one of the online units to be a back-up for
maintenance and test purposes.
0 = Removed force back-up situation
1 = SSPA #1 is forced to be a back-up
2 = SSPA #2 is forced to be a back-up

FBU= (message ok)
FBU? (received ok, but
invalid arguments
found)

FBU? FBU=x

(same format as
command
arguments)

Remote Address

SPA=

4 bytes,
numeric

Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412

SPA= (message ok)
SPA? (received ok, but
invalid arguments
found)

SPA?

SPA=x
(same format as
command
arguments)

Remote Baud

Rate

SBR= 4

bytes

Command or Query.
Set remote baud rate as follows:
9600 = 9600 baud
19K2 = 19200 baud

SBR= (message ok)
SBR? (received ok, but
invalid arguments
found)

SBR?

SBR=xx

(same format as
command
arguments)

Set RTC(Real-

Time-Clock) Date

DAT= 6

bytes,

numeric

Command or Query.
A command in the form mmddyy, where; dd = day
of the month, between 01 and 31, mm = month of
the year, between 01 and 12 and yy = year,
between 00 and 96 (2000 to 2096)
Example: DAT=042503 would be April 24, 2003

DAT= (message ok)
DAT? (received ok, but
invalid arguments
found)
DAT* (message ok, but
not permitted in current
mode)

DAT?

DAT=xx

(same format as
command
arguments)

Set RTC Time

TIM=

6 bytes,
numeric

Command or Query.
A command in the form hhmmss, indicating the
time from midnight, where hh = hours, between 00
and 23; mm = minutes, between 00 and 59, and ss
= seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12
minutes and 59 seconds from midnight.

TIM = (message ok)
TIM? (received ok, but
invalid arguments
found)
TIM * (message ok, but
not permitted in current
mode)

TIM?

TIM=xx

(same format as
command
arguments)

Clear All Stored

Alarms

CAA= None

Command

only

Instructs the slave to clear all Stored Events
This command takes no arguments.

CAA= (message ok)

N/A

N/A

Serial Number

N/A

9 bytes, numeric

000000000 to

999999999

Query only.
Used to Query the units 9 digit serial number.
Slave returns its S/N, in the form xxxxxxxxx.
Example: RSN=000000165

N/A RSN?


RSN=xxxxxxxxx
(see description
for details of
arguments)

Retrieve

Equipment Type

N/A 22

bytes,

alpha-numeric

Query only.
The unit returns a string indicating the Model
Number and the the value of internal software
revision installed
Example: RET=CPA-300 VER: 1.0.3

N/A RET?


RET=x….x

(see description
for details of
arguments)