4.5.14 Restart (All)
This command allows the user to reset/restart the converter.
@01/RESTART
4.5.15 Data (All)
This command will cause the converter to display the applicable data formats for the various
commands.
@01/DATA
4.5.16 Learn (B1:1, B1:8)
In a 1:1 Switch configuration, this command will cause the backup converter to ‘Learn’ about the
Prime converter.
In a 1:8 configuration, the Backup converter will ‘Learn’ about the Prime converters that have a
priority > 0. As the Backup converter polls the Prime(s), the learning status will be output via the
serial port.
@01/LEARN
4.5.17 Show Priority (B1:8)
This command causes the backup converter to display the priority settings for all 8 of the prime
converters.
@01/SHOW PRI (1:8 configuration only)
4.5.18 Set Priority (B1:8)
This command is used to set the priorities of converters 1 to 8 respectively where:
0 = No priority (the converter will be ignored)
1 = Highest priority
8 = Lowest Priority
@01/SETPRIabcdefgh (1:8 configuration only)
For example: @01/SETPRI47300000 will cause the following to occur:
Converter 1 will have priority 4;
Converter 2 will have priority 7;
Converter 3 will have priority 3;
Converters 4 through 8 will be ignored.