Comtech EF Data SFC4200 User Manual
Page 47
SFC4200/SFC1275G Synthesized Frequency Downconverter
User Interfaces
TM054 - Rev. 4.0
4-23
Note: For a 1:1 Switch configuration, if the front panel switch is accidentally left in
Manual Mode, then the following action should be performed: from the Remote Port, send
a manual command to the converter that is ‘Manually Deselected,’ i.e.; the one that is NOT
selected. Then send an Auto Command to the same converter and the switch change
back to Auto Mode.
For a 1:8 Switch configuration, send the Auto Mode command to the backup converter.
4.5.9 Manual Mode Command (P1:1, B1:1)
This command allows the operator to force the switch to put the converter online and keep it
there. This command simulates the manual selection switch on the front panel. Issue the
following command:
@01/MANUAL
Note: For a 1:1 Switch configuration, if the front panel switch is accidentally left in
Manual Mode, then the following action should be performed: from the Remote Port, send
a manual command to the converter that is ‘Manually Deselected,’ i.e.; the one that is NOT
selected. Then send an Auto Command to the same converter and the switch change
back to Auto Mode.
4.5.10 Manual Backup Command (B1:8)
This command allows the operator to force the switch to put the Backup online for the specified
converter and keeps it there. This command simulates the manual backup selection switches on
the front panel of the 1:8 Switch. Issue the following command:
@01/MANBACKn
Where:
n = 0 Forces the Backup to Standby Mode, all Primes are online
n = 1 – 8 Specifies the converter that the Backup is to replace
4.5.11 Set Stored Gain For a Specified Channel (S, P1:1, P1:8)
This command allows the user to set the Stored Gain for a specified channel other than the
current one.
@01/RAMGAINccsgg.g
4.5.12 Set Stored Frequency For a Specified Channel (S, P1:1, P1:8)
This command allows the user to set the Stored Frequency for a specified channel other than the
current one.
@01/RAMFREQccffff.t
4.5.13 Erase (All)
This command allows the user to erase the Stored Status, Frequency and Gain Information the
next time the unit is reset.
@01/ERASE