EQ90 REV 2 ERRATA A.DOC
1
Errata A
Comtech EFData Documentation Update
Subject:
Changes to Table 2-2. Summary Alarm Interface Connector J3 Pin
Assignments
Date:
October 18, 2000
Document:
EQ90 Group Delay/Amplitude Equalizer Installation and Operation
Manual, Rev. 2, dated June 14, 1998
Part Number:
MN/EQ90.EA2
Collating Instructions:
Attach this page to page 2-5
Comments:
The following changes provide additional Table 2-3 and updates to paragraph 2.3.1. This
information will be incorporated into the next revision.
Change Specifics:
Table 2-3. Summary Alarm Interface Connector J3 Pin Assignments
Pin No.
Assignment
1,2
Not Used
3
Normally Open (Equalizer Operational). Referenced to pin 4.
4 Common
5,6 Not
Used
7
Alarm Out (Open, Equalizer Operational). Referenced to pin 8.
8 Alarm
Common
9
Normally Closed (Equalizer Operational). Referenced to pin 4.
2.3.1 Channel Monitor
The alarm monitor output connector (J3) provides a summary fault status output to a summary
alarm panel, or annunciator type device, or redundancy switching equipment. Refer to Table 2-3
for pin assignments.