Chapter 4. Configuration

menu> (Ref. Figure 2)

There are five (5) configuration modes to select from:

System Type: Selects between a Standalone System and a 1:1 Redundant System.

Signal Path: Select Signal Path to view and change Upconverter Frequency, Upconverter
Amplifier attenuation, Mute ON/OFF, Downconverter Frequency, Downconverter attenuation,
and Mute ON/OFF XSAT parameters.

LNA: Select LNA to view and change Current
Source (ON/OFF), XSAT Fault Logic
(ON/OFF), the allowable Current Window,
and the percent Current change. Reference the
menu item 7 (LNA Configuration) for
additional information.

Miscellaneous: Select Miscellaneous to view
or change Cold Start, Auto Fault Recovery
(AFR), Local Reference Oscillator
Adjustment, External Reference Fault Logic,
and Up and Down converter slope adjustments.

Redundancy Controller: Online Unit
(XSAT) selector, Operating Mode
AUTO/MAN, RF/IF switch status OK/FT,
Controller Voltages (monitoring 5VDC and
12VDC.


Figure 2