Manual programming guide, Temperature menu (if equipped) – CompX eLock Network Fridge User Manual

Page 7

background image

7

Manual Programming Guide

Temperature Menu (if equipped)

CompX eLocks equipped with temperature monitoring have a

number of features that can be adjusted in the TEMPERATURE

MENU using manual programming.

TURN ON/OFF ALARM

1 Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press

“ENTER.”

3. Using the “UP”/“DOWN” button, highlight TEMPERATURE

MENU and press “NEXT/SELECT.”

4. A) TURN ON ALARM will appear if alarm is disabled. Press

“NEXT/SELECT” to enable the alarm. Alarm Now

ENABLED will appear.

B) TURN OFF ALARM will appear if alarm already is enabled.

Press “NEXT/SELECT” to disable the alarm. Alarm Now

DISABLED will appear.

RESET OBSERVED TEMPERATURES

(OBSERVED TEMPERATURES IS THE HIGHEST AND LOWEST TEMPERATURE
THAT HAS BEEN RECORDED SINCE THE LAST TIME THE eLock WAS RESET.
THIS WILL NOT RESET THE UPPER AND LOWER LIMITS FOR ALARMING.
IF THE ALARM TEMPERATURE LIMITS NEED TO BE CHANGED, SEE

TEMPERATURE LIMITS)

1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press

“ENTER.”

3. Press “DOWN” button to highlight TEMPERATURE MENU and

press “NEXT/SELECT.”

4. Using the “UP”/“DOWN” button, highlight RESET OBS. TEMPS

and press “NEXT/SELECT.”

5. Reset high and low temperature observations? will appear.

Press ‘UP” and “NEXT/SELECT” to reset.

6. Observations RESET will be displayed.

TEMPERATURE LIMITS

(THE TEMPERATURE RANGE CAN BE ADJUSTED IN 1/10TH DEGREE
INCREMENTS)

Temperature ranges:
Standard Temp eLock: -40°C to 100°C (-40°F to 212°F)
Ultra Low Temp eLock: -100°C to -40°C (-148°F to -40°F)

1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press

“ENTER.”

3. Press “DOWN” button to highlight TEMPERATURE MENU and

press “NEXT/SELECT.”

4. Using the “UP”/“DOWN” button, highlight TEMP LIMITS and

press “NEXT/SELECT.”

5. ALARM SETTINGS will appear along with the current

MINIMUM

TEMP & MAXIMUM TEMP

settings.

6. Press “UP”/“DOWN” buttons to select value and +/- buttons

or numeric keypad to adjust.

7. Press “NEXT/SELECT” when done.

ALARM SETTINGS

(USING ALARM SETTINGS, ALARM VOLUME, ALARM DELAY, ALARM
DURATION AND THE CHIRP WARNING CAN BE ADJUSTED)

Note: Supervisor level status is required to Enable/Disable

the alarm using ALARM SETTINGS.

CHIRP

serves two purposes. First, it is an early warning that

the temperature being recorded has gone outside of the

programmed acceptable range. Second, if the temperature

alarm is disabled, the CHIRP feature allows the eLock to

sound an alert.

When

CHIRP

is “ON” it will sound at the programmed volume

(OFF, SOFT, MED, LOUD)

and escalate at the programmed speed

(OFF, SLOW, MED, FAST)

until the programmed

ALARM DELAY

time

has expired and the eLock starts to alarm, or the temperature

goes back in the programmed acceptable range.

1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press

“ENTER.”

3. Press “DOWN” button to highlight TEMPERATURE MENU and

press “NEXT/SELECT.”

4. Using the “UP”/“DOWN” button, highlight ALARM SETTINGS

and press “NEXT/SELECT.”

5. Alarm Settings will appear along with

CHIRP ON/OFF; CHIRP

VOLUME; CHIRP ESCALATION

6. Press “UP”/“DOWN” buttons to select and +/- buttons or

numeric keypad to adjust:

ALARM VOLUME (OFF, SOFT, MED, LOUD)
ALARM DELAY (MINUTES)
ALARM DURATION (MINUTES)
CHIRP (ON/OFF)
CHIRP VOLUME (OFF, SOFT, MED AND LOUD)
CHIRP ESCALATION (OFF SLOW, MED, FAST)

7. Press “NEXT/SELECT” when done.