CompX eLock Temperature Monitoring Programming User Manual
Temperature monitoring, Compx elock, Unit

Temperature Monitoring
Note: not actual size; shown at 150%
B
C
A
G
D
E
E
I
F
H
J
CompX eLock
®
unit
A: Green LED indicator of successful open cycle
B: Red LED indictor of unsuccessful attempt
C: Asterisk button used to clear entry or remove user /
supervisors
D: Pound button used to insert PIN or program new users /
supervisors
A
Basic unit Features:
k
Records 8,000 temperature events
k
Accuracy within +/- 1˚C
k
Single probe, mounted in non-toxic glycol bottle
k
Easy to read LCD display
k
Operating range of from -40˚F to 122˚F (-40˚C to 50˚C)
k
Requires 6 AA batteries (9V) not included
General functionality:
k
Pressing the scroll up arrow will display the maximum
temperature that the monitor has recorded
k
Pressing the scroll down arrow will display the minimum
temperature that the monitor has recorded
k
Pressing the key will display the current date
k
Pressing the key twice will display the day of the week
1
CompX eLock
®
unit
CompX eLock
®
temperature display keypad
***IMPORTANT INFORMATION***
This unit comes with factory reset codes/cards. Please save the attached stickers/cards and place in a secure location. This unit can
be reset to original Factory Set-up Mode by entering the factory reset code or presenting the factory reset card. CAUTION: ENTERING
THE FACTORY RESET MODE WILL ERASE ALL USERS/SUPERVISORS THAT ARE CURRENTLY PROGRAMMED IN THE LOCK.
A
C
D
B
CompX eLock
®
temperature
display keypad
A: Minimum and maximum temperature limits
B: Unit is unlatched. This icon is not visible when latching
mechanism is in the locked position.
C: Programming mode
D: Bell icon indicates alarm is enabled. Flashing bell sound waves
means the alarm is sounding. Flashing bell means the alarm
has been muted. Does not indicate alarm volume setting:
soft-medium-loud.
E: Degree sign and unit of temperature measure. Will either show
˚C or ˚F.
F: Display of time or temperature or setting.
G: Back button
H: Scroll up button
I: Enter button
J: Scroll down button