INSTRUCTIONS FOR THE INSTALLER
Choosing the type of gas (5-burner version)
The hob can be configured for use with natural gas or LPG. To activate the gas selection procedure
the hob must be switched on with all of the burners off.
Press the “+” and “-” buttons simultaneously for approx. 3 seconds as shown in the figure above.
The burner level display will switch off and “Met” or “LPG” will appear on the timer display,
depending on the current configuration.
met
Select the desired setting using the “+” and “-” buttons.
met
To complete the procedure, press the timer button.
By activating this function, any other previously set burner switch off times will be cancelled.