INSTRUCTIONS FOR THE INSTALLER
Electrical Connection
The appliance must be connected to the electrical mains by qualified personnel and in conformity
with statutory legislation.
The voltage of the electric supply must correspond to the value indicated on the label affixed to the
underside of the appliance.
Make sure that the electric system has an efficient earth connection in compliance with regulations
and legislation. This appliance must be earthed.
IMPORTANT: if the household electrical system does not meet specifications or does not have an
efficient earth connection, the appliance will not operate.
If the appliance is not fitted with a plug, connect a standard plug to the power cable.
If the appliance is to be wired directly to the mains supply, a disconnect device must be interposed
having a sufficient contact gap to allow complete isolation also in category
III surge conditions, in
accordance with installation regulations.
In case of a power failure, the appliance will not operate and the burners cannot be lit using
matches or external igniters.
However, the appliance can continue to operate correctly if the power cord is connected to an
uninterruptible power supply. In this case, operation is normal.
GAS CONVERSION AND ADJUSTMENTS
If the appliance is prearranged for a type of gas different from the available type, the burner
nozzles must be changed and the control card must be set up with the parameters relative to the
new configuration.
Changing the nozzles
Choose the required nozzles with reference to the following “Technical Specifications” table.
Proceed as follows:
- Remove the pan stands and burners from the hob.
- Unscrew nozzles U (fig.6) and U1/U2 (fig.7) using a socket spanner (L), and replace with the correct
nozzle for the available gas type.
- Secure the nozzle without over-tightening.
6
7