INSTRUCTIONS FOR THE USER
Electronic self-diagnosis
The circuit boards perform continuous self-diagnosis. In the event of hardware faults or
malfunctions in the circuit board that could be dangerous for the end user, the device will assume
“safe” mode, the solenoid valves are deactivated and the display shows the relative fault code.
Generally, the default operating parameters are restored by disconnecting and reconnecting the
power supply. This action will resolve most problems.
If the fault persists, contact your nearest service centre.
Fault types and codes are shown in the following table.
Fault type
Displayed fault
code
Solution
Single burner locked out
b
Perform reset procedure as
described in previous sections.
Spurious flame / flame detection circuit fault
on single burner
F
Disconnect electrical power
supply and then reconnect after
a few seconds.
If the problem persists, contact
the service centre.
Main valve control circuit fault
FLt00
Reference voltage circuit fault
FLt01
Watchdog circuit fault
FLt02
Microcontroller ports fault
FLt03
Eeprom fault
FLt04
Valve drive circuit fault
FLt05
Max 5 resets in 15 minutes exceeded
FLt06
Perform reset procedure as
described in previous sections.
Supply circuit fault
FLt08
Disconnect electrical power
supply and then reconnect after
a few seconds.
If the problem persists, contact
the service centre.
Resonator fault / Generic fault
FLt09
Perform reset procedure as
described in previous sections.
All burners locked out
FLt0A
Perform reset procedure as
described in previous sections.
Control logic communication errors
FLt0C
Disconnect electrical power
supply and then reconnect after
a few seconds.
If the problem persists, contact
the service centre.
Touch panel control error
FLt0E