PRE-INSTALLATION PREPARATION

Clearances
Framing and Finishing

PRE-INSTALATION PREPARATION

Continued

CLEARANCES

Minimum clearances to combustibles for the fi replace are as follows:

Back, and sides

0” (0 mm)

Perpendicular walls

10” (254 mm)

Floor

0” (0 mm)

Ceiling to louver opening 36” (914 mm)
Front

36” (914 mm)

Top

0” (0 mm)

B-Vent Surfaces

1” (26 mm) (See venting instructions

for

specifi cs on vent clearances.)

Mantel Clearances

(See - Mantel Clearances for specifi c

clearances to combustible mantels.)

Combustible material with a maximum thickness of 5/8” (16 mm)
may be fl ush with the top and sides of the front face of the fi replace.

PACKAGING AND REMOVAL

The (V)CB36 vented decorative gas fi replaces are packaged with:

- one box containg a 4-log set located on the burner in the fi rebox.

- one bag containing the owner’s manual with installation
instructions, operator’s guide, and warranty information.

- one bag of glowing ember material.

- one bag of vermiculite hearth treatments.

Remove the shrinkwrap securing the 2 carton trays to the unit.

Lift the top carton tray off and remove the four corner posts.

Discard the bottom tray once the unit is moved into position.

Note: To prvent damage to ceramic logs and glass panels you
may want to remove them before positioning and framing the unit.
To access fi rebox, see Hearth Access and Assembly, page ##.

Figure 4 - Unpacking Fireplace

FRAMING AND FINISHING

Figure 5 shows typical framing of this fi replace. Figure 6 shows
framing for corner installation. All minimum clearances must be met.

For overall unit dimensions, framing allowances, and vent collar
locations, see Unit Dimensions, Figure 7 on page 6.

For available accessories for this fi replace, see Accessories on page
33. If you are using a seperate combustible mantel piece, refer to
Figures 8 and 9 for proper height and clearances. You can install a
noncombustible mantel at any height above the fi replace opening.
Note: Non-combustible mantels may discolor!

Figure 5 - Framing Clearances for Flush, Wall Installation

Figure 6 - Framing Clearances for Corner Installation

14 3/4" (375 mm)

36 1/4" (921 mm)

36"

(914 mm)

2 x 4 FLAT

HEADER

FOR 1" OF CLEARANCE

AT THE SIDES AND BACK
OF THE FIREPLACE

IS ALSO PERMITTED AT

HOWEVER, 0" CLEARANCE

ALL SIDES WHEN FRAMED

THESE DIMENSIONS ALLOW

21" (533 mm)

TO CENTER OF

TOP VENT

14 3/4"

(375 mm)

TO NAILING

FLANGES

56 3/4"

(1441 mm)

12 1/4"

(311 mm)

TO

OPENING

28 5/8"

(727 mm)

14 3/4"