beautypg.com

Replacement parts, Service hints, Technical service – Desa (V) CB36(N User Manual

Page 27: Specifications

background image

26

www.desatech.com

117437-01

REPLACEMENT PARTS

SERVICE HINTS

SPECIFICATIONS

TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply
original replacement part(s), call DESA’s Customer Service De-
partment at 1-866-672-6040

When calling DESA, have ready

• your

name

• your

address

model and serial numbers of your fi replace

• how

fi replace was malfunctioning

type of gas used (propane/LP or natural gas)

• purchase

date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. Ifthey can not supply
original replacement part(s), call DESA’s Customer Service De-
partment at 1-866-672-6040

When calling DESA, have ready

model number of your fi replace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

• fi replace will not produce specifi ed heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local
gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA’s Customer Service Depart-
ment at 1-866-672-6040. When calling, please have your model and
serial number of your heater ready.

You can also visit DESA’s technical service web site at
www.desatech.com.

(V)CB36N

(V)CB36P

(V)CB36NE

(V)CB36PE

Max. Input Rating Btu/hr

18,000 Btu/hr

18,000 Btu/hr

18,000 Btu/hr

18,000 Btu/hr

Orifi ce Size (Main Burner)

#45 DMS (0.082")

#55 DMS (0.052")

#45 DMS (0.082")

#55 DMS (0.052")

Gas Type

Natural

Propane/LP

Natural

Propane/LP

Ignition

Millivolt

Millivolt

Electronic

Electronic

Manifold Pressure

3.5” w.c. (0.87 kPa)

10.0” w.c. (2.5 kPa)

3.5” w.c. (0.87 kPa)

10.0” w.c. (2.5 kPa)

Minimum Inlet Supply Pressure

5.5” w.c. (1.1 kPa)

11.0” w.c. (2.7 kPa)

5.5” w.c. (1.1 kPa)

11.0” w.c. (2.7 kPa)

Dimension, Inches/mm (HxWxD)

Fireplace (Actual size of fi rebox
measurements do not include
nailing fl anges or standoffs).

Carton

35 ¾"x 36 ¼" x 14 ¾"

908 x 921 x 375 mm

36 ¾" x 38" x 16 ¼"

933 x 965 x 413 mm

35 ¾"x 36 ¼" x 14 ¾"

908 x 921 x 375 mm

36 ¾" x 38" x 16 ¼"

933 x 965 x 413 mm

35 ¾"x 36 ¼" x 14 ¾"

908 x 921 x 375 mm

36 ¾" x 38" x 16 ¼"

933 x 965 x 413 mm

35 ¾"x 36 ¼" x 14 ¾"

908 x 921 x 375 mm

36 ¾" x 38" x 16 ¼"

933 x 965 x 413 mm

Fireplace Weight, lbs/kg
Shipping Weight, lbs/kg

98 lbs./45kg

101 lbs./46kg

98 lbs./45kg

101 lbs./46kg

102 lbs./47kg
105 lbs./48kg

102 lbs./47kg
105 lbs./48kg

SPECIFICATIONS