Using knife diagnostics, Cleaning the knife – Avery Dennison Monarch 9906 Knife User Manual
Page 5
Using Knife Diagnostics
You can use the Knife Diagnostics to move the knife back and forth. You may need to do this when
there is a jam or to clean the knife. See “Cleaning the Knife” for more information.
To access knife diagnostics, from the Main Menu select Diagnostics, User Diagnostics, then follow
these steps.
1.
Press or until you see Knife.
DIAGNOSTICS
←
Knife Maint
→
ENTER BACK
2.
Press CHANGE to highlight the knife diagnostics options.
3.
Press RevJog to move the knife slightly backward, FwdJog to move the knife slightly foward.
Any jammed supply should be removed from the knife. Press BACK to cut the supply and exit
knife diagnostics.
KNIFE MAINT
RevJog FwdJOG BACK
4.
Press BACK until you return to the Home/Online screen.
DIAGNOSTICS
← Knife Maint →
0
CHANGE
BACK
C l e a n i n g t h e K n i f e
Clean the knife regularly (approximately every 100,000 cuts) to reduce adhesive build-up.
CAUTION: Do not use alcohol, solvents, or degreasers to clean the knife.
1.
Turn off the printer.
2. Lightly
coat a long cotton swab (with a paper or plastic shaft, a wooden shaft could dull the
blade) with WD-40®. Never spray WD-40® directly on the printer or knife.