beautypg.com

Avery Dennison 9414 Equipment Manual User Manual

Page 33

background image

To c h a n g e y o u r p r i n t e r f r o m b l a c k m a r k t o g a p s e n s o r :

1. Measure in millimeters length of the label. Write

down this value for p

1

.

2. Measure the space between labels. Write down

this value for p

2

.

3. Convert the values to dots by multiplying the

millimeters by 8.

For example:
p

1

=20.0mm x 8 = 160 dots

p

2

=3.0mm x 8 = 24 dots

The EPL2 language consist of commands. The Q
Command sets the form length using the p

1

, p

2

and

p

3

values.

To set the Q command:

4. Open any text editor and open your format. Look

for the line that starts with Q (Q Command).

5. Type in the dot values for p

1

and p

2

.

For example:
Q160,24

6. Save file. Send format to your printer.

Label

Sensing the Supplies C-3