Safety label, Travis industries – Avalon Firestyles DVL Insert-1998 to 2001 User Manual
Page 30

2 8
Safety Label
Travis Industries
4 0 1 1 0 2 5
9 3 5 0 8 1 0 4
The safety (listing) label is on a plate chained to the gas control valve. A copy of the safety label is
shown below.
DVL Insert
Vented Gas Direct-V
ent Fireplace Heater
Tested and certified by OMNI-T
est Laboratories, Inc. to the combustion performance and construction requirements of
ANSI Z21.88
/CSA
2.33-1998,
applicable sections of UL
307b and CAN/CGA
2.17-M91.
The DVL
Insert is equipped from the factory only for use with Natural Gas. For conversion to LP
(Propane) use kit supplied by the
manufacturer
. This appliance
must be installed in accordance with all local codes, if any; if not, in USA
follow
ANSI Z223.1-1992 and NFP
A
54(88), in Canada C
AN/CGA
B-149. Installation
in Manufactured or Mobile Homes must conform with: In USA, Manufactured Home Construction and Safety Standard, T
itle 24 CFR, Pa
rt 3280; In Canada,
CSA
Z240.4 and Gas-Equipped Recreational V
ehicles and Mobile Housing. This appliance is only for use with the type of gas indica
ted on the rating plate
and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. Se
e owner
’s
manual for
details. This appliance is not convertible for use with other gases, unless a certified kit supplied by the manufacturer is use
d. See owner
’s
manual for
information on making these changes. This appliance uses a millivolt-type control system consisting of a gas control valve/regu
lator
, a standing pilot burner
assembly
, a thermopile, a thermocouple, a piezo ignitor
, and the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 1
10 VOL
T POWER T
O
OP
ERA
TE. All
exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area str
ucture.
This appliance is a V
ented Gas Fireplace Heater
. Not for use with Solid Fuel.
W
ARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the
owner
’s
information
manual provided with this appliance. For assistance or additional information consult a qualified installer
, service agency or
the gas supplier
.
W
ARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in car
bon monoxide (CO)
poisoning and possible death.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at
least annually by a qualified
service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present
. The control compartment,
the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s
installation instructions.
This vented gas fireplace heater is not for use with air filters.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or c
lothing ignition.
Young children should be carefully supervised at all times when they are in the same room as the appliance.
CAUTION:
Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors aw
ay
.
CAUTION:
Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a li
censed or qualified service person.
10850 1
17th Pl. N.E. Kirkland, W
A
98033
Minimum Clearances to Combustibles
Faceplate to
Adjacent W
all
. . . . . . . . . . . . . . . .
6” (155mm)
Faceplate to Mantel (from top of insert face)
. . . . . . .
10” (255mm)
Hearth Extension in Front
. . . . . . . . . . . . . . . . .
12” (305mm)
Faceplate to Front Facing
. . . . . . . . . . . . . . . .
. . . . . . .
8.5” (215mm)
Hearth Extension to Sides of Faceplate
. . . . . .
0” (0mm)
Flue V
ent
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . .
See Owner
’s Manual
FAN TYPE VENTED CIRCULA
T
O
R
Blower Electrical Rating: 1
15 V
., 1.5
Amps, 60 Hz, 150 watts
Steady State Efficiency
. . . . . . .
Up to 81% (blowers on)
Output Capacity Rating
. . . . . . .
Up to 32,400 (blowers on)
L.P
.
N.G.
L.P
.
N.G.
Input Rate on “HI” (BTU/Hr)
............
40,000
40,000
Minimum Inlet Pressure (inches W
.C.)
...............
11.5”
5.5”
Input Rate on “LO” (BTU/Hr)
...........
20,000
20,000
Maximum Inlet Pressure (inches W
.C.)
..............
13”
7”
Maximum Output (BTU/Hr)
..............
32,400
31,200
Manifold Pressure on “HI” (inches W
.C.)
..........
11
”
3.5”
Main Burner Orifice (DMS)
..............
#49
#31
Manifold Pressure on “LO” (inches W
.C.)
.........
2.7”
1”
This appliance is equipped for installation in Canada at 0-4500 ft. (0-1370 m); in USA, 0-2000 ft. (0-610 m).
In USA, for altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner
’s
manual for information on making these changes.