Installation, Vent location, Vent configurations – Avalon Firestyles DVL Insert-1998 to 2001 User Manual
Page 13

Installation
(for qualified installers only)
1 1
Travis Industries
4 0 1 1 0 2 5
9 3 5 0 8 1 0 4
Vent Location
2”
Center Line
Inlet (3” Dia.)
Exhaust (4” Dia.)
Fireplace
Opening
2-1/4”
13-7/8”
16”
13-1/4”
Vent Configurations
Z.C. (Metal) firebox
Inlet & Exhaust Re-Line
Exhaust Only Re-Line
(recommended)
Direct Vent Cap
(part # 991)
Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.
6-5/8" to 3" & 4" Colinear
Adapter & Flashing
(Travis Part # 98900124)
The block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(non-combustible
materials)
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
Inlet
Masonry Fireplace
Suggestion:
Paint the fireplace cavity
with latex paint to eliminate
the possibility of odors from
the fireplace circulating into
the room.
Any cracks or
damage inside the
chimney must be
repaired.
Exhaust
4" dia. UL 1777
Gas Liner
Inlet
3" dia. UL 1777
Gas Liner
Exhaust
4" dia. UL 1777
Gas Liner