Installation

(for qualified installers only)

1 1

Travis Industries

4 0 1 1 0 2 5

9 3 5 0 8 1 0 4

Vent Location

2”

Center Line

Inlet (3” Dia.)

Exhaust (4” Dia.)

Fireplace

Opening

2-1/4”

13-7/8”

16”

13-1/4”

Vent Configurations

Z.C. (Metal) firebox

Inlet & Exhaust Re-Line

Exhaust Only Re-Line

(recommended)

Direct Vent Cap

(part # 991)

Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.

6-5/8" to 3" & 4" Colinear

Adapter & Flashing

(Travis Part # 98900124)

The block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.

Block-Off Plate
(non-combustible
materials)

NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.

Inlet

Masonry Fireplace

Suggestion:
Paint the fireplace cavity
with latex paint to eliminate
the possibility of odors from
the fireplace circulating into
the room.

Any cracks or
damage inside the
chimney must be
repaired.

Exhaust

4" dia. UL 1777

Gas Liner

Inlet

3" dia. UL 1777

Gas Liner

Exhaust

4" dia. UL 1777

Gas Liner