Installation
(for qualified installers only)
1 5
Travis Industries
4 0 1 1 0 2 5
9 3 5 0 8 1 0 4
Manifold Removal and Installation (Continued)
Remove the glass (see the instructions on page 16). Follow the directions below to remove the
manifold.
N O T E : When replacing the manifold, use the convection top to guide the manifold. You may also reach
through the exhaust ducts to guide the manifold forward to the appropriate location.
Remove the four bolts
inside the firebox.
7/16”
Socket
5/16" Nutdriver
Remove the three screws holding
the convection top to the insert.
Convection Top
Manifold
Slide the
manifold
back.
NOTE: when installing the
manifold, make sure the
gaskets sealing the inlet and
exhaust ducts are in place. If
a gasket is loose, use high-
temperature silicone to
secure it to the manifold.
Shim the manifold legs if
installing into a fireplace
with a raised hearth.
Electrical Connection
•
Plug the power cord into a grounded 120 Volt outlet (do not remove the grounding pin).