Page 50: Travis industries

50
Optional Equipment
(
for qualified installers only)
50
Travis Industries
4150330
100-01408
3
Remove the screw on the lower duct plate and rotate it away to allow air to flow from the lower
convection channel (see pictures below). NOTE: This plate is not removed, it is swiveled out of the
way – use a screwdriver, if necessary to rotate the plate.
Installing the Power Heat Duct with the 564 HO
The power heat duct must be installed in accordance with the instructions included with the kit and all
local codes. See the illustration below for an overview
Starter Ring
Use 10” x 3-1/4”
wall stack (duct)
when passing
through tight
areas.
6" Duct
Duct Adapter
(6” Round to 10” x 3-1/4”)
Floor
Boot
Grill
Rheostat
(with cover plate)
Junction Box
Wall Adapter
(for use on
2 x 4 walls)
Blower
Box
Maximum Duct
Length = 20'
Electrical Source
Hot
(black)
Common
(white)
Ground
(green)
Power Supply
Hot
(black)
Common
(white)
Ground
(green)
Rheostat
Junction Box
Blower
Assembly