Installation, For qualified installers only) – Avalon Firestyles 564 HO GS2 Installation User Manual
Page 36

36
Installation
(
for qualified installers only)
36
Travis Industries
4150330
100-01408
Thick Facing Installation (stone, brick, or other non-combustible over 1" (25mm) thick)
If using a Fireplace Xtrordinair (FPX) arched face, see "Thick Facing with a Fireplace Xtrordinair Arched
Faces" on page 37.
Do not install masonry or other
material in front of the fireplace. This area
must remain open to install the face.
TOP VIEW - Protruding Masonry
Raised Fireplaces:
Masonry is installed 1” (25mm)
(maximum) above the base
of the fireplace.
Floor-Mounted Fireplaces or Raised Hearths:
Build the hearth 1” maximum (25mm) above the
base of the fireplace. The fireplaces may be raised
to accommodate thicker hearth materials.
29-1/4”
743mm
36-1/4”
921mm
1”
25mm
NOTE: The nailing brackets are not used for this type
of installation -- secure the fireplace to the floor with
the brackets along the base of the fireplace.
Masonry Line
Masonry Line
Hearth Line
Masonry Line
FRONT VIEW
Framing
Fireplace
Nailing Bracket
Drywall
Masonry
Framing
Fireplace
Drywall
Masonry
TOP VIEW - Recessed Masonry