2 introduction, Overview, Listing details – Avalon Firestyles 564 HO GS2 Installation User Manual
Page 2: Massachusetts approval, National fireplace institute, Caution

2 Introduction
© Travis Industries
4150330
100-01408
Overview
This manual details the installation requirements for
the 564 HO NB GSR2 fireplace. For operating and
maintenance instructions, refer to the 564 HO NB
GSR2 Owner's Manual (part # 100-01409).
Listing Details
This appliance was listed by Intertek Test Labs to
ANSI Z21.88. The listing label is attached to the
appliance near the gas control valve. A copy is
shown to the right.
Massachusetts Approval
This manual has been submitted to the
Massachusetts Board of State Examiners of
Plumbers and Gas Fitters.
National Fireplace Institute
Report No. B100307498PRT
-001
Control No. 4000515
Certified for USA
and Canada
Te
sted to:
ANSI Z21.88-2009/CSA
2.33-2009 “V
ented Gas Fireplace Heaters”, CGA
2.17-M91, UL
307b-2006 “Gas Burning Heating
Appliances for Manufactured Homes”, and CSA
P
.4.1-09.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI
Z223.1/NFP
A
54, or Natural Gas and Propane Installation Codes, CSA
B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA
Z240 MH, Mobile Housing, in Canada or with
the Manufactured Home Constructions and Safety Standard, T
itle 24 CFR, Part 3280, in the United States, or when such a
standard is not applicable,
ANSI/NCSBCS
A225.1/NFP
A
501A, Manufactured Home Installation Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,
the
optional factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured home (USA
only) where not prohibited by local codes. See owner
’s
manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s installation instructions.
Use only approved coaxial direct vent system to vent this appliance to the exterior
. See owner
’s
manual for approved brands of
venting.
W
A
RNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to
the owner
’s
information manual provided with this appliance. For assistance or additional information consult a qualified
installer
, service agency or the gas supplier
.
CAUTION:
Hot while in operation. Do Not T
ouch. Severe burns may result. Keep children,
clothing, furniture, gasoline and other liquids having flammable vapors away
. Do not operate
this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be
done by a licensed or qualified service person.
VENTED GAS FIREPLACE HEA
T
ER - NOT FOR USE WITH SOLID FUEL
MINIMUM CLEARANCES T
O
COMBUSTIBLES
Fireplace to
Adjacent W
all
W
o
od Floor Beneath Fireplace
Back to Enclosure
12” (305 mm)
0” (0 mm)
0” (0 mm)
Base of Fireplace to Enclosure T
o
p
Sides to Enclosure
Base of Fireplace to a 12” Mantel*
(*See manual for other mantel depths)
56” (1423 mm)
0.5” (13 mm)
48.75” (1239 mm)
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
35,000
7,500
35,000
10,400
Minimum Inlet Pressure (inches W
.C.)
Maximum Inlet Pressure (inches W
.C.)
Manifold Pressure on “HI” (inches W
.C.)
11
”
13”
10”
5.5”
7”
3.5”
For natural gas when equipped with the following drill size orifice: DMS 50 Front - DMS 44 Back
For propane when equipped with the following drill size orifice: 1.10mm Front - DMS 55 Back
This appliance is equipped for use only at altitudes 0-2000 feet (0-610m) in the USA. In Canada, 0-4500 feet (0-1370m).
For altitudes above 2000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner
’s manual for information on making these changes.
Electrical Rating: 1
15V
., 60 Hz, 1.5
Amps
L.P
.
N.G.
L.P
.
N.G.
201
1
2012
2013
Jan.
Feb.
Mar
.
Apr
.
May
Jun.
Jul.
Aug.
Sep.
Oct.
Nov
.
Dec.
Manufacture
Date:
www
.travisproducts.com
0962