beautypg.com

Installation, For qualified installers only) – Avalon Firestyles 564 HO GS2 Installation User Manual

Page 28

background image

28

Installation

(

for qualified installers only)

28

Travis Industries

4150330

100-01408

Vent Configurations with Horizontal Termination (Dancing/DiamondFyre)

 The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and

diffuser positions.

 Up to four elbows (45° or 90°) may be used.
 Only one horizontal elbow may be used.

NOTE: With no vertical rise, LP installations have a maximum run of 2 feet (0.6m); NG installations have a
maximum run of 4 feet (1.2m).

5 feet (1.5m)

0 feet

20 feet (6m)

20 feet (6m)

10 feet (3m)

15 feet (4.5m)

0 feet

5 feet (1.5m)

10 feet (3m)

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

21' max (6.4m)

21' max (6.4m)

Exhaust Restrictor # 5

2’ LP/4’ NG Maximum

Exhaust Restrictor #1
Intake Restrictor #1
Diffuser Position #1 (CLOSED)

Exhaust Restrictor #3
Intake Restrictor #2
Diffuser Position #2 (OPEN)

Exhaust Restrictor #4
Intake Restrictor #3
Diffuser Position #2 (OPEN)

Exhaust Restrictor #4
Intake Restrictor #5
Diffuser Position #2 (OPEN)

0 feet

5 feet (1.5m)

10 feet (3m)

15 feet (4.5m)

20' max (6m)

5 feet (1.5m)

0 feet

.

H1

H2

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a vertical elbow.

Horizontal length (max. 24’) is calculated

by adding both lengths of horizontal run

(Horizontal Length = H1 + H2).