beautypg.com

Installation – Avalon Firestyles 564 HO GS2 Installation User Manual

Page 19

background image

Installation

(

for qualified installers only)

19

Travis Industries

4150330

100-01408

Gas Line Location

NOTE FOR RIGID PIPE: When using rigid pipe, you may wish to disconnect the shutoff valve from the fireplace
and route the pipe through the fireplace wall. First, disconnect the gas line from the shutoff valve (see step 1
below). Then remove the shutoff valve from the cover plate (4 screws outside fireplace). The pipe may be routed
through the cover plate and the shutoff valve and gas line may be re-attached inside the fireplace.

Converting Gas Line to the Left Side

1. Disconnect the gas line from the shutoff valve (3/4” wrench). Gas line is located inside the fireplace

on the right side.

2. Remove the screw that holds the shutoff valve plate in place (1/4” nutdriver). Remove the shutoff

valve plate.

3. Remove the cover plate from the left side of the fireplace (it is held in place in the same fashion as

the shutoff valve plate). Attach it to the right side of the fireplace.

4. Attach the shutoff valve plate to the left side of the fireplace. Route the gas line to the left side and

re-attach the gas line to the shutoff valve. Make sure to leak test the entire gas line.

8.75"
223mm

15 Degrees

3" (77mm) Above Base

7"

178mm

Right Side Gas Line (Stock)

Left Side Gas Line

3" (77mm) Above Base

15 Degrees