beautypg.com

Audio Enhancement TLD100 User Manual

Page 12

background image

12

Plasma television screens generate infrared interference. It is not recommended to use a plasma

display in the same room where the TLD100 is installed.
However, if a plasma screen must be used, install it in the following way and after confirming
operation, use it very carefully.

Install the infrared sensor in a location where side and back of plasma display cannot be seen, and install it as far

away as possible (more than 10 m {33 feet}).

The distance between the infrared sensor and microphone should be as short as possible (within 3 m {10 feet})

while in use.


Do not put any blocks (including the human body) between the infrared sensor and microphone while in use.

Even after following these recommendations, interference may still occur.

The distance between a fluorescent lamp and the infrared sensor should be as far apart as possible

(more than 1 m {3.3 feet}) in installing.

If a remote controller such as an audio-visual device or air conditioner is controlled by an infrared

sensor, noise or sound breaks may occur.

If there are any other devices making strong noises, product may sometimes be impossible to use.

In that case, install the product farther away until it can be used.

Ceiling height is expected to be 2 m {7 feet} to 4 m {13 feet}. If it is out of this range, the arrival range

may be shortened.

The base color of wall, floor, and ceiling should be white or light colors. With black or dark color

surfaces, the arrival range may be shortened.

A reflection from the wall is used in the arrival range. If the wall is far away from the area of use, the

arrival range may be shortened.

Sound breaks may occur near windows or in rooms with a lot of windows. In this case, it may be

useful to use light-colored curtains or window shades.

If a microphone is used near and facing a wall, sound breaks may occur.

For tightening bolts and screws, pay attention to the following points:

Torque control is necessary for tightening the bolts and screws.

Torque wrench and torque driver are necessary for controlling the torque.

Never use any impact driver or electric drill because torque control is difficult even if they have a clutch. Their use

may result in damage to the mounting part.

After mounting, confirm visually that the product is firmly and stably fixed. If the product is properly

installed, it will not wobble or make noise.

In installing this infrared sensor, be aware of the following:

Be sure that the installation is carried out by qualified personnel when installing at high locations.

Before installation, confirm that there is nobody around.

In order to carry out the installation safely and surely, pay close attention to the safety control.

The supplied safety strap shall be used.

Be sure to firmly secure the safety strap to the ceiling mount bracket at installation.

Precaution for installation place and securing of the conversion box:

The conversion box shall be installed on a stable place such as on a shelf and secured with screws as necessary.

Do not apply strong force to this unit. Failure to observe this may damage this unit.