Audio Enhancement TLD100 User Manual
Page 12
12
•
Plasma television screens generate infrared interference. It is not recommended to use a plasma
display in the same room where the TLD100 is installed.
However, if a plasma screen must be used, install it in the following way and after confirming
operation, use it very carefully.
①
Install the infrared sensor in a location where side and back of plasma display cannot be seen, and install it as far
away as possible (more than 10 m {33 feet}).
②
The distance between the infrared sensor and microphone should be as short as possible (within 3 m {10 feet})
while in use.
③
④
Do not put any blocks (including the human body) between the infrared sensor and microphone while in use.
Even after following these recommendations, interference may still occur.
•
The distance between a fluorescent lamp and the infrared sensor should be as far apart as possible
(more than 1 m {3.3 feet}) in installing.
•
If a remote controller such as an audio-visual device or air conditioner is controlled by an infrared
sensor, noise or sound breaks may occur.
•
If there are any other devices making strong noises, product may sometimes be impossible to use.
In that case, install the product farther away until it can be used.
•
Ceiling height is expected to be 2 m {7 feet} to 4 m {13 feet}. If it is out of this range, the arrival range
may be shortened.
•
The base color of wall, floor, and ceiling should be white or light colors. With black or dark color
surfaces, the arrival range may be shortened.
•
A reflection from the wall is used in the arrival range. If the wall is far away from the area of use, the
arrival range may be shortened.
•
Sound breaks may occur near windows or in rooms with a lot of windows. In this case, it may be
useful to use light-colored curtains or window shades.
•
If a microphone is used near and facing a wall, sound breaks may occur.
•
For tightening bolts and screws, pay attention to the following points:
①
Torque control is necessary for tightening the bolts and screws.
②
Torque wrench and torque driver are necessary for controlling the torque.
③
Never use any impact driver or electric drill because torque control is difficult even if they have a clutch. Their use
may result in damage to the mounting part.
•
After mounting, confirm visually that the product is firmly and stably fixed. If the product is properly
installed, it will not wobble or make noise.
•
In installing this infrared sensor, be aware of the following:
①
Be sure that the installation is carried out by qualified personnel when installing at high locations.
②
Before installation, confirm that there is nobody around.
③
In order to carry out the installation safely and surely, pay close attention to the safety control.
•
The supplied safety strap shall be used.
Be sure to firmly secure the safety strap to the ceiling mount bracket at installation.
•
Precaution for installation place and securing of the conversion box:
The conversion box shall be installed on a stable place such as on a shelf and secured with screws as necessary.
•
Do not apply strong force to this unit. Failure to observe this may damage this unit.