21 stop-all-monitors, Table 4-9, Start-diag-scan – Artesyn ViewCheck on ATCA-9405 Installation and Use (November 2014) User Manual
Page 57: Commands execution

Commands Execution
ViewCheck on ATCA-9405 Installation and Use (6806800S51F)
57
The following table provides the start-diag-scan command arguments.
Syntax for XML
]]>]]>
4.2.21 stop-all-monitors
stop-all-monitors
command stops all the monitors of the mentioned device category.
Table 4-9 start-diag-scan
Argument
Data Type
Description
Dev category-N
String
Name of the device category. You can specify multiple
device category using comma ’,’ in between.
Itr-num
Integer
Enter the number of times that diag-scan has to run. By
default, value is "1".
Maximum number of iterations that user can specify is
1000.
halt-string
String
Type "Yes" or "No".
haltOnError
specifies whether to continue or stop
with test case execution on the occurrence of any error.
By default, value is "No".
timeout-val
Integer
Enter the maximum time period to be taken by each test
to execute.
- ViewCheck on ATCA-7480 Installation and Use (April 2015) ViewCheck on ATCA-7370 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (November 2014) ViewCheck on ATCA-F140 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (September 2014) ViewCheck on ATCA-9405 Installation and Use (May 2014) ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (May 2014)