6
D. HEATER ON/OFF SWITCH
The heater on/off switch supplies power to the heating
unit when main on/off switch (A) is on.
E. HEATER THERMOSTAT CONTROL
To adjust the temperature to your individual
requirements, turn the thermostat control clockwise all
the way to turn on the heater. When the room reaches
the desired temperature, turn the thermostat knob
counter clockwise until you hear a click. Leave in this
position to maintain the room temperature at its setting.
For additional heat, turn clockwise until you hear the click
again and the heater will turn on. To lurn the heater off,
rotate the knob fully counter clockwise.
NOTE
• The heater may emit a slight, harmless odor when first
used. This odor is a normal condition caused by initial
heating of internal heater parts and will not occur again.
3. To conceal the controls during operation, return the
grill to its original upright position.
WARNING
-Disconnect power before attempting any maintenance or
cleaning to reduce the risk of fire, electric shock or
damage to persons.
Light Bulb Replacement:
NOTE
·
Allow at least 5 minutes for light bulbs to cool off before
touching bulbs to avoid accidental burning of skin.
Light bulbs need to be replaced when you notice a dark
section of the flame or when the clarity and detail of the
log exterior disappears. There are two bulbs at the top of
the opening which illuminate the log set exterior, and four
bulbs under the log set which generate the flames and
embers.
Tool Requirements: Slot Screw Driver
FIGURE 10 (a,b,c)
REMOVING GLASS
REPLACING GLASS
a
b
c
HOLDING GLASS
RETAINING CLIP
MAINTENANCE