7.3.3.3. Capture Buffer Mode and Capture Forward Mode
A: This field shows the number of packets and number of captured packets.
B: If you set Capture Forward Mode under Instant mode, this field will be available for settings:
¾
You can enable Auto Save by clicking the check box, and see the status of captured packets on
a designated folder by clicking Status button. Or you can save the instant status by clicking the
Save button.
¾
You can also initiate the packets capture operation by clicking Start Capture button, and stop the
packets capture operation by clicking the Stop Capture button.
C: In this field, you can check the status of each captured packet based on the order of packet (No.),
Delta Time(us), Length(with CRC), Destination/Source MAC address, VLAN, Protocol and
Destination/Source IP.
D: This field shows the packet/frame view items, such as Ethernet II. User can click to expend the
sub-tree on the Item Name column, and see the value of network frame on the Value column.
E: Shows the data based on the field C.
7.3.4. Report: USC A/B
The Report shows the Rule chosen on the Stream Counter Mode settings for each USC A and USC B.
Please refer to the 7.2.3. USC A & USC B for more details.