Menu operations, 5] gpi – TVLogic XVM-175W User Manual
Page 21
Multi Format LCD Monitor 21
●
This product provides a REMOTE
CONTROL mode. The user may connect
RJ-45 jack to the REMOTE terminal on the
rear of the unit and designate a function
for each pin.
●
The default settings are as follows:
PIN 1 : ANALOG CHANNEL
PIN 2 : SDI-A CHANNEL
PIN 3 : SDI-B CHANNEL
PIN 4 : PBP CHANNEL
PIN 5 : TALLY R
PIN 6 : TALLY G
PIN 7 is POWER ON/OFF use only, PIN 8 is GND
- Use the ENTER button and UP/DOWN button
to set the desired function.
XVM-175WD
SDI A
[5] GPI
5. Menu Operations
PAGE I >> PAGE II
GPI 1
GPI 2
GPI 3
GPI 4
GPI 5
GPI 6
GPI 7
GPI 8
ANALOG CHNNEL
SDI-A CHANNEL
SDI-B CHANNEL
PBP CHANNEL
TALLY R
TALY G
POWER ON
GND
REMOTE (RJ-45)
1: Pin1
2: Pin2
3: Pin3
4: Pin4
5: Pin5
6: Pin6
7: Pin7
8: GND
1
8
Menu
Classifi-
cation
Settable Values
PIN
1~6
NONE, ANALOG CHANNEL, SDI-A
CHANNEL, SDI-B CHANNEL, PBP
CHANNEL, TALLY R, TALLY G,
UNDER SCAN, 1:1 SCAN, ASPECT,
H/V DELAY, BLUE ONLY, MONO,
16:9 MARKER, 4:3 MARKER, 4:3
ON AIR MARKER, 15:9 MARKER,
14:9 MARKER, 13:9 MARKER, 1.85:1
MARKER, 2.35:1 MARKER, 1.85:1&4:3
MARKER, CENTER MARKER, SAFETY
AREA 80%, SAFETY AREA 85%,
SAFETY AREA 88%, SAFETY AREA
90%, SAFETY AREA 93%, SAFETY
AREA 100%, 708, 608(LINE21),
608(ANC), OP47, OP42, TELETEXT
PAGE 801, TELETEXT PAGE 888,
TELETEXT PAGE 889
PIN 7
POWER ON/OFF CONTROL
PIN 8
GND
XVM-175W_245W-N_325W-EN_V2.4.indd 21
2014-02-12 오후 5:36:19