Menu operations, 5] gpi, Menu classifi- cation settable values – TVLogic LVM-247W User Manual
Page 19

Multi Format LCD Monitor 19
●
This product provides a REMOTE
CONTROL mode. The user may connect
RJ-45 jack to the REMOTE terminal on the
rear of the unit and designate a function for
each pin.
●
The default settings are as follows:
PIN 1 : ANALOG CHANNEL
PIN 2 : MODE CHANNEL
PIN 3 : PBP CHANNEL
PIN 4 : TALLY R
PIN 5 : TALLY G
PIN 6 : TALLY Y
PIN 7 is POWER ON/OFF use only, PIN 8 is GND
- Use the ENTER button and UP/DOWN button
to set the desired function.
LVM-247W
SDI A
[5] GPI
5. Menu Operations
PAGE I >> PAGE II
GPI 1
GPI 2
GPI 3
GPI 4
GPI 5
GPI 6
GPI 7
GPI 8
ANALOG CHNNEL
MODE CHANNEL
PBP CHANNEL
TALLY R
TALY G
TALY Y
POWER ON
GND
REMOTE (RJ-45)
1: Pin1
2: Pin2
3: Pin3
4: Pin4
5: Pin5
6: Pin6
7: Pin7
8: GND
1
8
Menu
Classifi-
cation
Settable Values
PIN
1~6
NONE, ANALOG CHANNEL, SDI A
CHANNEL, SDI B CHANNEL,
PBP CHANNEL, TALLY R, TALLY G,
TALLY Y, UNDER SCAN, 1:1 SCAN,
ASPECT, H/V DELAY, BLUE ONLY,
MONO, 16:9 MARKER, 4:3 MARKER,
4:3 ON AIR MARKER, 15:9 MARKER,
14:9 MARKER, 13:9 MARKER,
1.85:1 MARKER, 2.35:1 MARKER,
1.85:1&4:3 MARKER, CENTER
MARKER,
SAFETY AREA 80%, SAFETY AREA
85%, SAFETY AREA 88%,
SAFETY AREA 90%, SAFETY AREA
93%, SAFETY AREA 100%, 708,
608(LINE 21), 608(ANC), DYNAMIC-
UMD
PIN 7
POWER ON/OFF CONTROL
PIN 8
GND