21 

 

SC2400 Operations ‐ Settings 

Weld Counter and Weld Counter Reset 

The SC2400 is equipped with different counters to display the number of times the unit has drawn 
an arc or the stud gun has been actuated. 

Perpetual Weld Counter (Non‐resettable) ‐ This is a running total of every time an arc is drawn on 
the machine. This is programmed from the factory and can not be reset.  

Perpetual Gun Counter (Non‐resettable)  ‐  This is a running total of every time the stud gun is 
actuated whether an arc was drawn or not. 

Job Counter (Resettable) ‐  This is a running total of the number of welds since the counter was 
last reset. To view the job counter, set the Fine/Coarse Switch to the Fine position. Each weld will 
be recorded on the Current digital display. If the switch is in the Coarse position, the weld will still 
be counted, but will not be displayed. You can also view the Job Counter total by depressing the 
Adjustment Dial while the switch is in the Coarse position.  

 

To Reset the Job Counter; 

1.  Turn off unit. 

2.  Depress and hold down Time and Current buttons. 

3.  Turn on machine. 

4.  Keep holding down buttons until OUTPUT light flashes then release the buttons. 

5.  Job Counter will now be set at 0. 

6.  Weld count will now register on Current digital display. 

 

Job Counter will display here 

Press down and hold