Sc2400 operations ‐ settings, Sc2400 power switch/power on, Sc2400 diagnostic lights – Tru-Weld SC2400 Arc Welder User Manual
Page 19
![background image](https://www.manualsdir.com/files/770777/content/doc019.png)
19
SC2400 Operations ‐ Settings
SC2400 Power Switch/Power On
The power switch for the SC2400 is located on the right front of
the welder’s control panel. When the power is turned on to the
unit, the light on the power switch will be illuminated.
When the welder is turned on, the digital display will go through a
self‐diagnostic check. This takes approximately 3 to 5 seconds,
and then the digital display will show the last time and current
setting.
This denotes that the unit is ready to go.
When connected to the welder, the stud gun will actuate 3 times,
indicating that there is a good connection.
SC2400 Diagnostic Lights
On the Control Panel, located below the digital display, is a row of diagnostic lights for the
welder.
OUTPUT ‐ When the stud gun is triggered, this light comes on to indicate that the OCV is present
at the output terminals.
TRIGGER ‐ When the stud gun is triggered, this light comes on to indicate that the trigger circuit is
functioning properly, and that the welding unit is receiving feedback from the stud gun.
POWER ‐ When this light is lit, it indicates that there is an error.
TEMP ‐ When this light is lit, it indicates that either the main transformer or weld bridge has
reached maximum temperature and that the unit will not function until it is cooled.
REMOTE ‐ This function is not currently in use.
Diagnostic Lights