14
SC2400 Setup and Installation
Weld Cable Connections
♦
The SC2400 is equipped with two weld cable connections located in the front of the welder
(lift access panel).
♦
One end of the cable assembly connects directly to the SC2400 and the other end connects to
the cabling from the weld gun. The welder end will have a cable lug on the Heavy Duty 4/0
Weld Cable and a male 4‐pole plug on the Control Cable.
♦
Tighten weld cable lug to welder .
♦
Plug Control Cable plug into port on bottom front of welder (lift access panel). The Control
Cable has a male 4‐pole connector on one end that plugs into the port.
Figure 1 ‐ Front of SC2400
Access Panel
Weld Cable Connection
Control Cable Connection
After the cables are connected to the welder, it is time to configure your weld gun for its
specific job. Once the gun is configured and set up properly, the gun cables will connect to
the weld cables. For the SC2400, the weld cable ends that connects to the Heavy‐Duty
TWE17000 Stud Gun will be a female Control Cable Plug and a female Heavy‐Duty High
Temperature camlock connector.