beautypg.com

Lighting – Toyotomi Omni 230 User Manual

Page 9

background image

LIGHTING

NOTE: When you first use your new heater, ignite it out of the living area of your house, either in a garage or an

outside area protected from strong drafts. Burn it for about 15 minutes to remove all of the protective oil

present on the burner parts. lf this 15 minutes “burn-in” is done inside, some objectionable odor will be

observed. This procedure is necessary ONLY THE FIRST TIME you ignite your heater.

NOTE: lf you have fueled your heater for the first time, or if you are refueling it after it has been out of fuel for a

long time, you will need to wait about thirty (30) minutes for the wick to become fully saturated before

Iighting. Failure to allow enough time for the wick to become fully saturated may cause permanent damage

to the wick when it is lighted.

1. Turn the wick adjuster knob clockwise until it stops.

It makes a spark discharge sound in the process of lighting procedure, but turn the

wick adjuster knob clockwise until it stops.

As the wick rises within the heater, the wick adjuster knob turns with some

resistance and makes a sound like the winding of a clock. Once the wick has

reached its proper height, the automatic extinguisher is fully engaged.

The wick adjuster knob can now move freely left or right to adjust the flame.

2. LIGHTING WITH A MATCH

You should not have to light the heater with a match, but should it become

necessary, open the access door, lift the heat chamber up by holding the wire

handle and touch the match to the top of the wick. DO NOT allow burned parts of

the match to fall or remain on the wick.

NOTE: To restore the automatic igniter system to proper operation, replace worn-

out batteries, or if the igniter coil defective, replace it.

3. Be sure that heat chamber is properly seated by moving the wire heat chamber

handle left and right, and close the access door.

NOTE: An improperly seated heat chamber can cause high flame, smoke, and

potential damage to the heater itself. DO NOT leave the heater until you

have determined that the flame is burning normally, as described in the

following section.

8

Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 8