beautypg.com

Troubleshooting – Toyotomi Omni 230 User Manual

Page 17

background image

TROUBLESHOOTING

16

PROBLEM

Wick fails to ignite

Smoke or odor

Flickering, dying or
low flame

Wick adjuster knob
is hard to turn

Flame too high

CAUSE

Out of fuel

Electrode does not spark

Water in kerosene (paraffin)/
poor quality kerosene (paraffin)

Heat chamber tilted or
improperIy seated

Wick set too high

Dirty wick

Drafts

Contaminated fueI/poor quality
kerosene (paraffin)

Dirty wick

Water in kerosene (paraffin)/
poor quality kerosene (paraffin)

Wick too low to sustain good
flame

Dirty wick

Poor quality kerosene (paraffin)

Damaged mechanism

Fuel contaminated with
gasoline (petrol) or other highly
flammable material

Wick set too high

SOLUTlON

Check fuel gauge; add fuel if necessary.

Check wire connections. Replace batteries.
Replace igniter unit, if necessary.

Drain tank. Install new wick.
Refill with fresh, clean kerosene (paraffin).

Move wire handle until heat chamber is
properly seated and moves smoothly left
and right.

Reduce wick height by turning wick adjuster
knob counterclockwise. Check position of
the wick life extender.

Clean wick as described under “Care and
Maintenance”.

Relocate heater.

Drain tank and rinse with clean kerosene
(paraffin). lnstall new wick and refill with
fresh, clean kerosene (paraffin).

Clean wick as described under “Care and
Maintenance”.
lf necessary, install new wick.

Drain tank and rinse with clean kerosene
(paraffin). lnstall new wick and refill with
fresh, clean kerosene (paraffin).

Replace the wick life extender to step 2 or
3. If already at step 3, replace wick.

Clean wick as described under “Care and
Maintenance”.

Drain tank and rinse with clean kerosene
(paraffin). Install new wick and refill with
fresh, clean kerosene (paraffin).

Contact your dealer for service.

lMMEDIATELY shut off heater.
lnspect all components for damage.
Drain tank and rinse with clean kerosene
(paraffin). lnstall new wick and refill tank with
fresh, clean kerosene (paraffin).

Check the position of the wick life extender.

PAGE

7

6

12

8

9

11

2

11
12

11

12

11
12

9

12

11

11
12

3

11
12

9

Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 16