9. Tighten the four (4) wing nuts around the wick adjuster.

10. Turn the wick adjuster knob to be sure the wick moves smoothly up and down.

AFTER REPLACING THE WICK, CHECK THE OPERATlON OF THE AUTOMATlC

EXTINGUISHER.

Wick height on position 1 of the wick life extender should be 8 mm (5/16 in.) when

wick adjuster knob is turned fully cIockwise. Be sure to check.

NOTE:

Remember always to start a new wick on position 1 of the wick life

extender.

NOTE: lf wick does not move smoothly and easily, or wick height on position 1 of

the wick life extender is not in the range of 7-9 mm (9/32-5/16 in.).

DO NOT use heater. Disassemble and repeat items 5 through 10.

NOTE: lf any ragged edges appear on the top of the wick, trim them with a

scissors carefully. DO NOT cut the body of the wick.

11. Replace the outer cover on the fuel tank and secure it into position with three (3)

screws by using the screwdriver. Replace batteries in the battery holder.

12. Once again, check the proper operation of the automatic extinguisher.

NOTE: Before lighting a new wick for the first time, turn the wick to its lowest

position and allow the wick to saturate with kerosene (paraffin) for about

thirty (30) minutes.